Proline Promass 300 Endress Hauser-Books Pdf

Proline Promass 300 Endress Hauser
15 Nov 2019 | 67 views | 0 downloads | 28 Pages | 1.09 MB

Share Pdf : Proline Promass 300 Endress Hauser

Download and Preview : Proline Promass 300 Endress Hauser


Report CopyRight/DMCA Form For : Proline Promass 300 Endress Hauser



Transcription

Proline Promass 300,Table of contents,Manufacturer s Declaration 3. Safety related characteristic values 4,Useful lifetime of electric components 6. Document information 6,Document function 6,Using this document 6. Symbols used 6,Supplementary device documentation 7. Permitted device types 9,SIL label on the nameplate 10.
Safety function 10,Definition of the safety function 10. Restrictions for use in safety related applications 10. Use in protective systems 12,Device behavior during operation 12. Parameter configuration for safety related applications 13. Proof testing 20,Life cycle 23,Requirements for the personnel 23. Installation 23,Commissioning 24,Operation 24,Maintenance 24. Repairs 24,Modification 24,Decommissioning 24,Appendix 25.
Structure of the measuring system 25,Verification or calibration 26. Notes on the redundant use of multiple sensors 26,Version history 26. 2 Endress Hauser, Proline Promass 300, Manufacturer s Declaration. A0031602 EN,Endress Hauser 3, Proline Promass 300. Safety related characteristic,values,General, Device designation and permitted versions 8A3B Promass A 300 .
8E3B Promass E 300 , 8F3B Promass F 300 , 8H3B Promass H 300 . 8I3B Promass I 300 , 8O3B Promass O 300 , 8P3B Promass P 300 . 8Q3B Promass Q 300 , 8S3B Promass S 300 , 8X3B Promass X 300 . Order code for Output input 1 , Option BA 4 20mA HART . Option BB 4 20mA Wireless HART , Option CA 4 20mA HART Ex i .
Option CB 4 20mA Ex i Wireless HART , Order code for Output input 2 . All options, Order code for Output input 3 , All options. Order code for Additional approval , Option LA SIL . Safety related output signal 4 to 20 mA output input 1 . Error current 3 6 mA or 21 mA, Assessed measured variable function Monitoring of mass flow volume flow or density. Safety function s Min Max Range, Device type according to IEC 61508 2 Type A Type B.
Operating mode Low Demand Mode High Demand Mode Continuous Mode 1 . Valid hardware version main electronics From delivery date August 2 2016. Valid firmware version 01 00 zz and higher HART from delivery date August 2 2016 . Safety manual SD01727D, Type of assessment Complete HW SW assessment in the context of development including FMEDA and change. only 1 version can be selected process according to 61508 2 3. Assessment of evidence for proven in use HW SW including FMEDA and change process. according to 61508 2 3, Analysis of HW SW field data for evidence of prior use according to IEC 61511. Assessment by FMEDA according to IEC 61508 2 for devices without software. Assessment by including Report No FMEDA T V Rheinland Industrie Service GmbH Certificate No 968 FSP 1306 00 16. data source , Test documents Development documents test reports data sheets. SIL integrity, Systematic safety integrity SIL 2 capable SIL 3 capable. Hardware safety integrity Single channel service HFT 0 SIL 2 capable SIL 3 capable. Multi channel service HFT 1 SIL 2 capable SIL 3 capable. FMEDA,Safety function s Min Max Range, Option BA BB Option CA CB.
2 , DU 121 FIT 117 FIT, 2 , DD 1366 FIT 1346 FIT,4 Endress Hauser. Proline Promass 300, SU 2 871 FIT 1067 FIT, 2 , SD 1308 FIT 1295 FIT. SFF Safe Failure Fraction 97 97 , 3 ,PFDavg for T1 1 year 5 3 10 4 5 1 10 4. single channel architecture ,PFDavg for T1 4 years 3 2 1 10 3 2 0 10 3. single channel architecture ,PFH 6 1 10 8 5 8 10 8.
PTC 4 Up to 98 , 5 ,MTBFtot 66 years 55 years, 6 ,Diagnostic test interval 30 min. 7 ,Fault response time 30 s, 8 ,Process safety time 50 h. Recommended test interval T1 4 years, 9 ,MTTFd 77 years 78 years. Note, The measuring device has been developed for use in Low Demand and High Demand mode . Explanation, Our in house quality management system saves information on safety related systematic errors that will become known in the future .
1 No continuous operation as per IEC 61508 2011 section 3 5 16 . 2 FIT Failure In Time number of failures per 109 h. 3 Valid for averaged ambient temperatures up to 40 C 104 F in accordance with general standard for devices with SIL capability . 4 PTC Proof Test Coverage diagnostic coverage achieved by device failure detection during manual proof testing . 5 This value takes into account all failure types of the electronic components as per Siemens SN29500. 6 All diagnostic functions are carried out at least once during this time . 7 Maximum time between fault detection and fault response . 8 The process safety time amounts to the diagnostic test interval 100 calculation as per IEC 61508 . 9 MTTFd as per ISO 13849 IEC 62061 also includes soft errors sporadic bit errors in data memories . Endress Hauser 5, Proline Promass 300, Useful lifetime of electric The established failure rates of electrical components apply for a useful lifetime of 12 years as per. components IEC 61508 2 2010 Section 7 4 9 5 Note 3 . The device s year of manufacture is coded in the first character of the serial number table below . Example serial number L5ABBF02000 year of manufacture 2016. ASCII character Meaning ASCII character Meaning ASCII character Meaning. D 2010 K 2015 R 2020, E 2011 L 2016 S 2021, F 2012 M 2017 T 2022. H 2013 N 2018 V 2023, J 2014 P 2019 W 2024, Document information. Document function The document is part of the Operating Instructions and serves as a reference for application specific. parameters and notes , General information about functional safety SIL. General information about SIL is available , In the Download Area of the Endress Hauser Internet site www de endress com SIL.
Using this document Information on the document structure. For the arrangement of the parameters as per the Operation menu Setup menu Diagnostics. menu along with a short description see the Operating Instructions for the device. For information about the operating philosophy see the Operating philosophy chapter in the. device s Operating Instructions,Symbols used Safety symbols. Symbol Meaning, DANGER , DANGER This symbol alerts you to a dangerous situation Failure to avoid this situation will. result in serious or fatal injury , WARNING , WARNING This symbol alerts you to a dangerous situation Failure to avoid this situation can. result in serious or fatal injury , CAUTION , CAUTION This symbol alerts you to a dangerous situation Failure to avoid this situation can. result in minor or medium injury , NOTE , NOTICE This symbol contains information on procedures and other facts which do not result in.
personal injury , Symbols for certain types of information. Symbol Meaning, Tip, Indicates additional information . Reference to documentation, A Reference to page,6 Endress Hauser. Proline Promass 300, Symbol Meaning, Reference to graphic. Notice or individual step to be observed, 1 2 3 Series of steps.
Result of a step, Operation via local display, Operation via operating tool. Write protected parameter, Symbols in graphics, Symbol Meaning. 1 2 3 Item numbers, A B C Views, A A B B C C Sections. Supplementary device For an overview of the scope of the associated Technical Documentation refer to the following . documentation The W M Device Viewer Enter the serial number from the nameplate. www endress com deviceviewer , The Endress Hauser Operations App Enter the serial number from the nameplate or scan the. 2 D matrix code QR code on the nameplate , Standard documentation.
Operating Instructions, Measuring device Documentation code. Promass A 300 BA01482D, Promass E 300 BA01484D, Promass F 300 BA01485D. Promass H 300 BA01486D, Promass I 300 BA01487D, Promass O 300 BA01488D. Promass P 300 BA01489D, Promass Q 300 BA01490D, Promass S 300 BA01491D. Promass X 300 BA01492D, Description of Device Parameters.
Measuring device Documentation code, Promass 300 GP01057D. Endress Hauser 7, Proline Promass 300, Technical Information. Measuring device Documentation code, Promass A 300 TI01270D. Promass E 300 TI01272D, Promass F 300 TI01221D, Promass H 300 TI01273D. Promass I 300 TI01274D, Promass O 300 TI01275D, Promass P 300 TI01276D.
Promass Q 300 TI01277D, Promass S 300 TI01278D, Promass X 300 TI01279D. Supplementary device dependent documentation, Safety Instructions. Contents Documentation code, ATEX IECEx Ex d Ex de XA01414D. ATEX IECEx Ex ec XA01514D, cCSAus XP XA01515D, cCSAus Ex d Ex de XA01516D. cCSAus Ex nA XA01517D, INMETRO Ex d Ex de XA01518D.
INMETRO Ex ec XA01519D, NEPSI Ex d Ex de XA01520D. NEPSI Ex nA XA01521D, Remote display and operating module DKX001. Contents Documentation code, ATEX IECEx Ex i XA01494D. ATEX IECEx Ex ec XA01498D, cCSAus IS XA01499D, cCSAus Ex nA XA01513D. INMETRO Ex i XA01500D, INMETRO Ex ec XA01501D, NEPSI Ex i XA01502D.
NEPSI Ex nA XA01503D, Special Documentation, Contents Documentation code. Information on the Pressure Equipment Directive SD01614D. Remote display and operating module DKX001 SD01763D. 8 Endress Hauser, Proline Promass 300, Installation Instructions. Contents Documentation code, Installation Instructions for spare For an overview of the accessories available for order see the Operating. part sets Instructions for the device, Permitted device types. The details pertaining to functional safety in this manual relate to the device versions listed below. and are valid as of the specified software and hardware versions Unless otherwise specified all. subsequent versions can also be used for safety functions A modification process according to IEC. 61508 is applied for any device modifications , Feature Designation Option selected.
Order code 8A3B Promass A 300 , 8E3B Promass E 300 . 8F3B Promass F 300 , 8H3B Promass H 300 , 8I3B Promass I 300 . 8O3B Promass O 300 , 8P3B Promass P 300 , 8Q3B Promass Q 300 . 8S3B Promass S 300 , 8X3B Promass X 300 , 000 Nominal diameter All. 010 Approval transmitter sensor All, 015 Power supply All.
1 , 020 Output input 1 Option BA 4 20mA HART , Option BB 4 20mA Wireless HART . Option CA 4 20mA HART Ex i , Option CB 4 20mA Ex i Wireless HART . 021 Output input 2 All, 022 Output input 3 All, 030 Display Operation All. 040 Housing All, 050 Electrical connection All, 060 Measuring tube mat wetted surface All. 070 Process connection All, 080 Calibration flow All.
480 Device model All, 500 Display operating language All. 520 Sensor option All, 530 Customer specific configuration All. 540 Application Package All, 2 , 550 Suitability for custody transfer measurement All. 570 Service All, 580 Test certificate All, 590 Additional approval LA SIL 3 . 610 Accessory mounted All, 620 Accessory enclosed All.
Endress Hauser 9, Proline Promass 300, Feature Designation Option selected. 850 Firmware version Firmware with SIL capability e g 01 00 zz HART . 895 Marking All, 1 In devices with several outputs only current output 1 terminals 26 and 27 is suitable for safety functions . The other outputs can if necessary be connected for non safety oriented purposes . 2 Only for devices with approval for custody transfer. 3 Additional selection of further approvals is possible . SIL label on the nameplate, Order code , Ser no , Ext ord cd . i i, Date , 1, A0031473, 1 SIL logo, Safety function. Definition of the safety The measuring device s permitted safety functions are . function Monitoring of a maximum or minimum mass flow or a mass flow range for liquid or gaseous. media, Monitoring of a maximum or minimum volume flow or a volume flow range for liquid media.
Monitoring of a maximum or minimum density or a density range for liquid media. The safety functions are based on the simultaneous continuous measurement of the mass flow and. the density of a liquid , Safety related output signal. The measuring device s safety related signal is the 4 20 mA analog output signal output input 1 . All safety measures refer to this signal exclusively . In devices with several outputs only current output 1 terminals 26 and 27 is suitable for safety. functions The other outputs can if necessary be connected for non safety oriented purposes . The safety related output signal is fed to a downstream automation system where it is monitored for. the following , Overshooting and or undershooting of a specified limit value for the flow or the density of the. medium, The occurrence of a fault e g error current 3 6 mA 21 mA interruption or short circuit of. the signal line, Restrictions for use in safety Do not exceed the specifications indicated in the device documentation 7 . related applications, Dangerous undetected failures in this scenario.
An incorrect output signal that deviates from the value specified in the Operating Instructions but is. still in the range of 4 to 20 mA is considered a dangerous undetected failure . 10 Endress Hauser, Proline Promass 300, Detailed information concerning measured errors . 5 This value takes into account all failure types of the electronic components as per Siemens SN29500 6 All diagnostic functions are carried out at least once during this time 7 Maximum time between fault detection and fault response 8 The process safety time amounts to the diagnostic test interval 100 calculation as per IEC 61508

Related Books

Prayers of Saint Th r se WordPress com

Prayers of Saint Th r se WordPress com

During the days of His life on earth her Divine Son mysweet Spouse spoke 7 Sister Mary of St Peter entered the Carmel of Tours in 1840 Three years later she had the first of a series of revelations concerning devotion to the Holy Face as a means of reparation for blasphemy SeeLife of Leon Papin Dupont known as The Holy Man of Tours 8 Matt x 34 9 Cf Ps cxliii 1 2 5 Of a

Revelations of the Holy Face of Jesus BT041

Revelations of the Holy Face of Jesus BT041

convent Known as the Holy Man of Tours he was one of the most zealous promoters of Our Lord s request for reparation and devotion to the Holy Face He hung a large picture of the Holy Face in his parlor before which burned a lamp with holy oil This parlor which became an Oratory with the bishop s permission received countless

Workplace Expectations Samples Mesa Community College

Workplace Expectations Samples Mesa Community College

Workplace Expectations Samples 1 Explain work hours summer hours overtime guidelines used to start disciplinary action when it becomes a performance issue Employees who are unable to adhere to their posted schedule for any reason sickness running late personal issues etc must call their immediate supervisor as soon as possible This contact must be made either prior to or within

Policy Implementation Guideline Leaving Early from Work

Policy Implementation Guideline Leaving Early from Work

Policy Implementation Guideline Leaving Early from Work flexWorkLife Implementation Guideline Flexible Work Arrangements Leaving Early from Work POLICIES AND EXPECTATIONS GUIDELINES I Leaving Early From Work Policies The table below outlines policies that the organisation needs to consider when implementing a leaving early from work arrangement The policies can be amended according to

COPYRYGHT ELME TOOLS S L 2

 COPYRYGHT ELME TOOLS S L 2

2007 9 9 9 9 9 9 9 300 C Hemi CAN BUS 2005 9 DODGE CARAVAN 2001 2003 CARAVAN CAN BUS NOTA El receptor del Inmovilizador necesita ser reprogramado si este es substituido AVISO IMPORTANTE OPERACIONES GENERALES TIPOS DE LLAVES FUNCIONES ESPECIALES Seleccione CHRYSLER o DODGE en el menu de selecci n de vehiculos usando las flechas hacia arriba o hacia abajo Despu s

2008 Dodge PM Caliber Owner Guide Microsoft

2008 Dodge PM Caliber Owner Guide Microsoft

Caliber OWNER S MANUAL 2008 2 0 0 8 C a l i b e r 81 226 0839 First Edition Printed in U S A VEHICLES SOLD IN CANADA With respect to any Vehicles Sold in Canada the name Chrysler LLC shall be deemed to be deleted and the name Chrysler Canada Inc used in substitution therefor DRIVING AND ALCOHOL Drunken driving is one of the most frequent causes of accidents Your driving ability can be

Chrysler CANDataInterface2004 Up TABLE OF CONTENTS

Chrysler CANDataInterface2004 Up TABLE OF CONTENTS

This wire must be connected to hear sound from the factory amplifier DODGE Caliber 2007 2008 Charger 2006 2007 Dakota 2005 2007 Durango 2004 2007 Magnum 2005 2007 Ram 2500 3500 2009 Ram 2006 2008 Ram Chassis Cab 2006 2010 JEEP Commander 2006 2007 Compass 2007 2008 Grand Cherokee 2005 2007 Patriot 2007 2008 MITSUBISHI Raider 2006 2007 CHRYSLER 200 2011 2014 300 2008 2010 Aspen 2008 2009

AW INCH1 TABLE OF CONTENTS Chrysler CAN data interface 2004 up

AW INCH1 TABLE OF CONTENTS Chrysler CAN data interface 2004 up

DODGE Caliber 2007 2008 Charger 2006 2007 Dakota 2005 2007 Durango 2004 2007 Magnum 2005 2007 Ram 2500 3500 2009 Ram 2006 2008 Ram Chassis Cab 2006 2010 JEEP Commander 2006 2007 Compass 2007 2008 Grand Cherokee 2005 2007 Patriot 2007 2008 MITSUBISHI Raider 2006 2007 CHRYSLER 200 2011 up 300 Liberty 2008 2010 Aspen Patriot 2008 2009 Sebring Wrangler 2007 2010 Town amp Country 2008 up DODGE

06 11 DODGE CALIBER JEEP COMPASS P 07 11 W C S PART

06 11 DODGE CALIBER JEEP COMPASS P 07 11 W C S PART

page 2 1 remove the negative battery cable before installing the cruise control components for safety precau tions figure 1 2 jeep wrangler applications remove airbag by using trim tool to release 3 metal clips as shown in figure 2 3 dodge caliber jeep compass patriot applications remove airbag by extracting the 2 10mm screws as illustrated in figure 2a 4 press in sides of both

Daelim NS 125 DLX Service Manua firenzee com

Daelim NS 125 DLX Service Manua firenzee com

Service Information 1 7 Symbols Abbreviations The following symbols are used in this manual to represent job related warnings or cautions The following symbols indicate oil adding oil change or parts The following abbreviations are used in this manual ASS VY Assembly L Left R Right Symbol Meaning Add oil If there is no specific oil