Product Profile Rs Components-Books Pdf

PRODUCT PROFILE RS Components
27 Mar 2020 | 13 views | 0 downloads | 8 Pages | 1.25 MB

Share Pdf : Product Profile Rs Components

Download and Preview : Product Profile Rs Components


Report CopyRight/DMCA Form For : Product Profile Rs Components



Transcription

DESCRIPTION,ACCURATE RELIABLE PERFORMANCE RUGGED CONSTRUCTION. CURRENT MEASUREMENT BASED PROTECTION OVER MOLDED POWER CONNECTIONS. While electromechanical overload relays pass motor current The unique line side over molded power connections make for a. through heating elements to provide an indirect simulation of sturdy two component starter assembly that is unmatched in the. motor heating the E1 Plus Overload Relay directly measures motor industry The preformed power connections allow for easy starter. current Current measurement based overload protection more assembly every time. accurately models a motor s thermal condition Furthermore. ambient temperature does not impact the performance of current. CURRENT TRANSFORMERS, measurement based designs over the specified temperature. The current transformers are secured separately in the overload. operating range, housing to ensure the greatest degree of resistance to shock and. vibration conditions Varnished laminations ensure consistent. ELECTRONIC DESIGN, performance and provide additional protection against corrosion. Thermal modeling is performed electronically with precision. solid state components where at the heart of the E1 Plus. Overload Relay is an application specific integrated circuit LATCHING RELAY. ASIC The ASIC continually processes motor current data The robust design of the bipolar latching relay provides. to accurately maintain the time current status of the motor reliable trip and reset performance for the most demanding. thermal capacity utilization value of applications The self enclosed relay offers additional. environmental protection for use in industrial applications. THERMAL MEMORY, A thermal memory circuit allows the E1 Plus Overload Relay to.
APPLICATION FLEXIBILITY, model the heating and cooling effects of motor on and off periods. This ensures accurate protection for both hot and cold motors. ISOLATED CONTACTS, ENHANCED PHASE LOSS PROTECTION The isolated contact configuration allow the N C and N O contacts. A separate phase loss detection circuit incorporated into the E1 to be applied in circuits operating at different voltage levels and. Plus Overload Relay allows it to respond quickly to phase loss without polarity restrictions The AC15 B600 contact rating affords. conditions typical reaction time is 3 seconds application in circuits rated to 600V. DIP SWITCH SETTINGS,EASY TO SELECT AND APPLY, 193 EE and 592 EE devices offer DIP switch settings to select. the trip class 10 15 20 or 30 and the reset mode manual. STRAIGHTFORWARD INSTALLATION or automatic making these devices very versatile. The self powered design means that the E1 Plus Overload. Relay installs in the same manner as traditional overload relays. Device set up is accomplished by simply dialing the setting CAGE CLAMP TERMINALS. potentiometer to the motor FLA rating The low energy 193 EE devices offer optional cage clamp control terminals. consumption of the electronic design minimizes temperature that can reduce installation wiring time. rise issues inside control cabinets,WIDE ADJUSTMENT RANGE. A wide 5 1 adjustment range results in the need for half as many. catalog numbers as the bimetallic alternative in order to cover. the same current range This helps to reduce inventory carrying. costs and affords greater installation flexibility for dual voltage. machines Evenly spaced setting tick marks enhance the ease. of installation set up,FEATURE OVERVIEW,Identification Marking Strip.
Over Molded Power Stabs,Latching Mechanism,Test Button. Reset Button,Mechanical Trip Actuator,DIP Switches. 193 EE 592 EE only,Trip Status Indicator,Control Terminals. FLA Setting Dial,95 96 97 98,Load Terminations,WIDE 5 1 ADJUSTMENT RANGE. Ease in set up with evenly spaced settings,Simplified product selection with a minimized.
number of catalog devices greater overlap,Each device covers the range of nineteen. heater elements or four bimetallic devices,ENHANCED IEC STARTER ASSEMBLY. Rockwell Automation exclusive over molded power, stabs provides rigid interconnection with contactor. and simplifies assembly of starter, Greater stability is afforded with the overload relay. base being flush with the contactor base,Latching Mechanism.
Dimensions proportional to the contactor give an,integrated starter appearance and make control. panel design and installation straightforward, Enhanced starter assembly durability is provided by. the latching mechanism that mechanically locks the. E1 Plus to the base of the contactor,APPLICATION FLEXIBILITY. EE versions offer DIP switch adjustments for,selection of trip class and reset mode allowing. the use of one device for a broad range of,application requirements.
DIP switches are located on the side to limit, accessibility once installed for improved security. Trip class selections of 10 15 20 or 30,Reset mode selections include manual or. manual automatic,BULLETIN 193 ED IEC THREE PHASE DEVICES. Fixed Trip Class 10,Manual Reset,Mounts to Contractor Adjustment Range A Cat No. 0 1 0 5 193 ED1AB,0 2 1 0 193 ED1BB,100 C09 100 C23 1 0 5 0 193 ED1CB.
3 2 16 193 ED1DB,5 4 27 193 ED1EB,BULLETIN 193 EE IEC THREE PHASE DEVICES. Selectable Trip Class 10 15 20 30,Selectable Manual Auto Manual Reset. Screw Type Control Terminals,Mounts to Contractor Adjustment Range A Cat No. 0 1 0 5 193 EEAB,0 2 1 0 193 EEBB,100 C09 100 C23 1 0 5 0 193 EECB. 3 2 16 193 EEDB,5 4 27 193 EEEB,5 4 27 193 EEED,100 C30 100 C43.
9 45 193 EEFD,100 C60 100 C85 18 90 193 EEGE,30 150 193 EEHF. 100 D95 100 D180,40 200 193 EEJF,40 200 193 EEJG,100 D210 100 D420 60 300 193 EEKG. 100 500 193 EELG,120 600 193 EEMH,100 D630 100 D860. 160 800 193 EENH, Cage Clamp Control Terminals To order change the Bulletin number in the listed Cat No from 193 to 193R Example 193R EEFD. BULLETIN 592 EE NEMA THREE PHASE DEVICES,Selectable Trip Class 10 15 20 30.
Selectable Manual Auto Manual Reset,Mounts to Contractor Adjustment Range A Cat No. 0 1 0 5 592 EEAT,0 2 1 0 592 EEBT,1 0 5 0 592 EECT. 3 2 16 592 EEDT,0 2 1 0 592 EEBC,1 0 5 0 592 EECC,0 2 3 2 16 592 EEDC. 5 4 27 592 EEEC,9 45 592 EEFC,9 45 592 EEFD,18 90 592 EEGD. ACCESSORIES,Description For Use With Cat No,193 ED1 B 193 EE B 193 EPB.
DIN Rail Panel Adapter 193 EE D 193 EPD, For separate mounting can be mounted to top hat rail EN 50 02 35. 193 EE E 193 EPE,193 ED all,Current Adjustment Shield. Prevents inadvertent adjustments of the current setting 193 EE all 193 BC8. Package of 10 pieces,592 EE all,193 ED all,External Reset Adapter. For enclosed through the door reset applications 193 ERA. Use with External Reset Button,193 EE B 193 EE D 193 EE E. External Reset Button 193 ED all 800FM R611 Button. For enclosed through the door reset applications Metal construction IP66. non illuminated with rod length 142 mm adjustable range 141 159mm. Please consult the 800F catalog pages for additional types 193 EE B 193 EE D 193 EE E 800F ATR08 Rod. 193 EE all,Jam Protection Module with Remote Reset 193 EJM.
592 EE all,SPECIFICATIONS,MAIN CIRCUITS,Rated Insulation Voltage Ui 690V AC. Rated Impulse Strength Uimp 6 kV AC,Rated Operating Frequency 50 60 Hz. 193 B 193 D 193 E 592 All 690V AC IEC 600V AC CSA UL. Rated Operating Voltage Ue,193 F 193 G 193 H 1000V AC IEC 600V AC CSA UL. CONTROL CIRCUITS,Rated Insulation Voltage Ui 600V AC. Rated Impulse Strength Uimp 6 kV AC,Rated Designation B600.
Rated Operating Current Ie N O N C,12 120V 3 2,200 240V 1 5 1 5. 380 480V 0 75 0 75,500 600V 0 6 0 6,Thermal Current Ithe 5A. Contact Reliability 17V 5mA,ENVIRONMENTAL RATINGS,Storage 40 85 C 40 185 F. Ambient Temperature,Operating 20 60 4 140 F,Operating 5 95 non condensing. Damp Heat per IEC 68 2 3 and IEC 68 2 30,Vibration per IEC 68 2 6 3G.
Shock per IEC 68 2 27 30G,Maximum Altitude 2000m,Pollution Environment Pollution Degree 3. Degree of Protection IP20,PROTECTION, Type of Relay Ambient Compensated Time Delay Phase Loss Sensitive. Nature of Relay Solid State,Trip Rating 120 FLA,Type ED 10. Trip Class,Type EE 10 15 20 30,Type ED Manual,Reset Mode. Type EE Automatic or Manual, Standards UL508 CSA C22 2 No 14 NEMA ICS 2 1993 Part 4 EN 60947 4 1 EN 60947 5 1.
Approvals CE C tick CSA UL ATEX pending,APPROXIMATE DIMENSIONS. Dimensions are shown in millimeters inches Dimensions. are not intended to be used for manufacturing purposes. BULLETIN 193 E1 Plus Solid State Overload Relays,100 C Mounted. Overload Contactor A B C D E1 E2 F H1 H2,Cat No Cat No Width Height Depth. 193 ED B 100 C09 45 146 6 85 2 4 5 13 9 24 5 86 5 60 35. 193 EE B 100 C12 1 25 32 5 25 32 3 23 64 3 16 35 64 31 32 3 13 32 2 23 64 1 3 8. 193R EE B 100 C16,193S EE B 100 C23, 193 EE D 100 C30 45 146 6 101 2 4 5 13 9 24 5 104 60 35. 193R EE D 100 C37 1 25 32 5 25 32 3 63 64 3 16 35 64 31 32 4 3 32 2 23 64 1 3 8. 193 EE D 100 C43 54 146 6 101 2 4 5 18 9 24 5 104 60 45. 193R EE D 2 1 8 5 25 32 3 63 64 3 16 3 4 31 32 4 3 32 2 23 64 1 25 32. 193 EE E 100 C60 72 192 3 120 4 5 4 23 8 29 125 5 100 55. 193R EE E 100 C72 2 53 64 7 37 64 4 3 4 7 32 15 16 1 9 64 4 15 16 3 15 16 2 11 64. 193S EE E 100 C85, Publication 193 PP016C EN P September 2005 Copyright 2005 Rockwell Automation Inc All Rights Reserved Printed in USA.


Related Books

(Damour Campus) - Modern University for Business and Science

 Damour Campus Modern University for Business and Science

English Entrance Examination All new students are required to sit for English Placement Test. The test will classify students on the basis of their results. Students may submit their TOEFL scores if taken (iBT score of 65 or more is required). Math Placement Test Students applying to the Faculty of Business Administration and to the

Teaching and Learning Focus Group Facilitation: An ...

Teaching and Learning Focus Group Facilitation An

Teaching and Learning Focus Group Facilitation: An Encounter with Experiential Learning in a Graduate Sociology Classroom ... the acquisition and application of

ANTECEDENTS OF ENTREPRENEURIAL VALUES DOES GENDER STILL ...

ANTECEDENTS OF ENTREPRENEURIAL VALUES DOES GENDER STILL

eabaho@mubs.ac.ug Abstract This paper investigates the role of gender in the antecedence of entrepreneurial values. Data was collected from final year students from 12 universities and 21 degree programmes in Uganda. Multistage clustered and stratified proportionate sampling methods were used to select the respondents. Results indicate gender ...

Future IMO and ILO Legislation - Maritime Cyprus

Future IMO and ILO Legislation Maritime Cyprus

Annex I, were adopted which simplify the current entry. Implication: Not a substantial technical issue but Shipowners and Recognised Organisations should make sure that all certificates will be replaced. It is understood that the replacing timing will follow MSC-MEPC.5/Circ.7.

In thIs Issue: 4 12 14 - Wisconsin Historical Society

In thIs Issue 4 12 14 Wisconsin Historical Society

of Indian Nations of Wisconsin ... THE SOCIETy AND THE Pr IVATE Wisconsin ... able to honor our Wisconsin roots and share

Food and feed law - gov.uk

Food and feed law gov uk

Food and feed law: Compendium of UK food and feed legislation with associated context and changes during ... market and use of feed, tolerances for analytical constituents and feed additives in feed materials and compound feed, and labelling particulars for feed materials and compound feed for food- producing and non-food producing animals were amended. (Section 6.1) Case law Article 28 of ...

Notre Dame Press Releases - archives.nd.edu

Notre Dame Press Releases archives nd edu

Phyllis McGinley is the most highly respected contemporary writer of light verse. Her poems, essays and juvenile books, ... the Catholic Poetry Society Award, the ...

RNI No. GUJMUL/2017/74943 Posted at ... - dgps.gujarat.gov.in

RNI No GUJMUL 2017 74943 Posted at dgps gujarat gov in

724, Shaktivijay Society, Simada Road, Opp. Aakar Sport Club, Nana Varachha, Surat-395006. 69 Delvadiya Mehulbhai Raghavji Delvadiya Mehul Raghavji Shakti Plot, Street No. 5, Morbi-363641. 70 Siddharth Bhagvanjibhai Chaun Rajgor Siddharth Bhagvanjibhai Block No. M-31-165, Gujarat Housing Board, Opp Marketing Yard, Sanala Road, Morbi-363641.

CENTER: AHMEDABAD EXAM TYPE: ORAL(ONLY) - Gujarat State Portal

CENTER AHMEDABAD EXAM TYPE ORAL ONLY Gujarat State Portal

anupam society, sanala road, opp-g.i.d.c, morbi-363641 6 og-01-0006 bhagora govindbhai dalabhai g.h.board, sanala road, bl-430, 1nd floor, morbi 363641 7 og-01-0007 bhagora rajubhai manjibhai e type 288 urja nagar g s e l colony, at-ukai ta-songadh dist-tapi-394680t 8 og-01-0008 bhanderi sabir abdul pathan fali, b/h bhucharaji temple,

ONLY ORAL EXAM- AHMEDABAD - ceiced.gujarat.gov.in

ONLY ORAL EXAM AHMEDABAD ceiced gujarat gov in

anupam society, sanala road, opp-g.i.d.c, morbi-363641 ahmedabad 8 30218001352 og-01-0008 bhagora govindbhai dalabhai g.h.board, sanala road, bl-430, 1nd floor, morbi 363641 ahmedabad 9 30218001305 og-01-0009 bhagora rajubhai manjibhai e type 288 urja nagar g s e l colony, at-ukai ta-songadh dist-tapi-394680t ahmedabad 10 30218001363 og-01-0010