Mpa Smc Etech-Books Pdf

MPa SMC ETech
17 Feb 2020 | 55 views | 0 downloads | 9 Pages | 961.20 KB

Share Pdf : Mpa Smc Etech

Download and Preview : Mpa Smc Etech


Report CopyRight/DMCA Form For : Mpa Smc Etech



Transcription

2 Color Display Digital Pressure Switch,For Air RoHS. ISE70 Series,The ISE70 series has been,Click here for details. How to Order,1 MPa ISE70 02 43 M,Piping specifications. N02 NPT1 4,F02 G1 4 ISO 1179,Output specifications With bracket. 2 settings,NPN open collector 2 outputs Pin no 2 4.
Fixed setting,43 NPN open collector 1 output Pin no 4. PNP open collector 1 output Pin no 2 A,65 PNP open collector 1 output Pin no 4. 2 settings,PNP open collector 2 outputs Pin no 2 4. Note Mounting screws,are not included,Unit specifications. Nil With display unit switching function Note 1,M Fixed SI unit Note 2.
Pressure unit psi Initial value,P Lead wire with M12 connector 5 m. With display unit switching function Note 1 S,Note 1 Under the New Measurement Law sales of. switches with the unit switching function are not Lead wire with M12 connector 5 m. allowed for use in Japan right angled,Note 2 Fixed unit MPa. Option Part No, When optional parts are required separately use the following part numbers to place an order. Option Part no Note,Bracket B and the bracket assembly.
make up one set, Bracket ZS 31 A Note Mounting screws are not included. Bracket assembly,Lead wire with M12 connector,ZS 31 B Lead wire length 5 m. Lead wire with M12 connector,ZS 31 C Lead wire length 5 m. right angled,2 Color Display Digital Pressure Switch. For Air ISE70 Series, Refer to pages 11 and 12 for Pressure Switch Precautions For details about the Specific Product Precau.
tions refer to the Operation Manual on the SMC website http www smcworld com Click here for details. Specifications,Model ISE70,Rated pressure range 0 to 1 MPa. Pressure display range Set pressure range 0 1 to 1 MPa. Withstand pressure 1 5 MPa ISE20, Pressure display resolution Set pressure resolution 0 01 MPa ZSE30. Applicable fluid Air Non corrosive gas Non flammable gas ISE30. Power supply voltage 12 to 24 VDC 10 Ripple p p 10 or less with power supply polarity protection ZSE40. Current consumption 55 mA or less at no load,Switch output. Output 27 2 settings NPN open collector 2 outputs Pin no 2 4 ISE10. Output 43 Fixed setting NPN open collector 1 output Pin no 4 PNP open collector 1 output Pin no 2 Note 1. Output 65 PNP open collector 1 output Pin no 4 ISE70. Output 67 2 settings PNP open collector 2 outputs Pin no 2 4. Max load current 80 mA ISE80,Max applied voltage 30 V at NPN output. Residual voltage 1 V or less with load current of 80 mA. Response time 2 5 ms with anti chattering function 20 ms 160 ms 640 ms 1000 ms 2000 ms ISA3. Short circuit protection With short circuit protection. Repeatability 0 5 F S ISA2,Hysteresis mode,Hysteresis.
Window comparator mode,Variable 0 or above, Display 3 digit 7 segment indicator 2 color display Red Green can be interlocked with the switch output Sampling cycle 5 times 1 s. Display accuracy 2 F S 1 digit at 25 C 3 C,Indicator light. OUT1 Light up when output is turned ON Green, OUT2 Light up when output is turned ON Red for output 27 67. Functions Anti chattering function Display unit switching function Zero clear function Keylock function ISG. Enclosure IP67 Note 2, Fluid temperature range 0 to 50 C No freezing or condensation ZSM1. Environ Operating temperature range Operating 0 to 50 C Stored 10 to 60 C No freezing or condensation. ment Operating humidity range Operating and stored 35 to 85 RH No condensation. Withstand voltage 1000 VAC for 1 minute between terminals and housing. Insulation resistance 50 M or more 500 VDC measured via megohmmeter between terminals and housing. Temperature characteristics,25 C reference within operating temperature range.
Standards CE UL CSA E216656 RoHS,Fitting C3604 electroless nickel plating. Wetted parts material,Sensor pressure receiving area Silicon O ring NBR. Port size 02 Rc1 4 N02 NPT1 4 F02 G1 4 ISO 1179 Note 3. Lead wire with connector Oilproof cable with M12 4 pin pre wired connector 4 cores 4 5 m Conductor O D 0 72 mm Insulator O D 1 14 mm. Weight 190 g excluding the lead wire with M12 4 pin pre wired connector. Note 1 The NPN and PNP outputs function for a single set point. Note 2 An FKM gasket is used for the product case seal Refer to the Operation Manual at SMC s website for details. Note 3 G1 4 Applicable to ISO 1179 1,2 Color Display Digital Pressure Switch. For General Fluids RoHS, ISE75 75H Series The ISE75 For 10 MPa series has been remodeled. Click here for details,How to Order,10 MPa ISE75 02 43 M.
15 MPa ISE75H 02 43 M,Piping specifications Made to Order. Specifications,N02 NPT1 4 X500 Analog voltage output. F02 G1 4 ISO 1179,Refer to page 87 for details,Output specifications Option 2. 2 settings Nil None,NPN open collector 2 outputs Pin no 2 4. With bracket,Fixed setting,43 NPN open collector 1 output Pin no 4.
PNP open collector 1 output Pin no 2,65 PNP open collector 1 output Pin no 4 A. 2 settings,PNP open collector 2 outputs Pin no 2 4. Unit specifications Note Mounting screws,are not included. Nil With display unit switching function Note 1,M Fixed SI unit Note 2. Pressure unit psi Initial value Nil None,With display unit switching function Note 1.
Lead wire with M12 connector 5 m,Note 1 Under the New Measurement Law sales of S. switches with the unit switching function are not, allowed for use in Japan Lead wire with M12 connector 5 m. Note 2 Fixed unit MPa right angled,Option Part No, When optional parts are required separately use the following part numbers to place an order. Option Part no Note,Bracket B and the bracket assembly. make up one set,Bracket ZS 31 A, Bracket assembly Note Mounting screws are not included.
Lead wire with M12 connector,ZS 31 B Lead wire length 5 m. Lead wire with M12 connector,ZS 31 C Lead wire length 5 m. right angled,2 Color Display Digital Pressure Switch. For General Fluids ISE75 75H Series, Refer to pages 11 and 12 for Pressure Switch Precautions For details about the Specific Product Precau. tions refer to the Operation Manual on the SMC website http www smcworld com Click here for details. Specifications,Model ISE75 ISE75H,Rated pressure range 0 to 10 MPa 0 to 15 MPa.
Pressure display range Set pressure range 0 4 to 10 MPa 0 5 to 15 MPa. Withstand pressure 30 MPa 45 MPa ISE20, Pressure display resolution Set pressure resolution 0 1 MPa ZSE30. Applicable fluid Fluid or gas that will not corrode stainless steel 304 430 and 630 ISE30. Power supply voltage 12 to 24 VDC 10 Ripple p p 10 or less with power supply polarity protection ZSE40. Current consumption 55 mA or less at no load,Switch output. Output 27 2 settings NPN open collector 2 outputs Pin no 2 4 ISE10. Output 43 Fixed setting NPN open collector 1 output Pin no 4 PNP open collector 1 output Pin no 2 Note 1. Output 65 PNP open collector 1 output Pin no 4 ISE70. Output 67 2 settings PNP open collector 2 outputs Pin no 2 4. Max load current 80 mA ISE80,Max applied voltage 30 V at NPN output. Residual voltage 1 V or less with load current of 80 mA. Response time 2 5 ms with anti chattering function 20 ms 160 ms 640 ms 1000 ms 2000 ms ISA3. Short circuit protection With short circuit protection. Repeatability 0 5 F S ISA2,Hysteresis mode,Hysteresis. Window comparator mode,Variable 0 or above, Display 3 digit 7 segment indicator 2 color display Red Green can be interlocked with the switch output Sampling cycle 5 times 1 s.
Display accuracy 2 F S 1 digit at 25 C 3 C,Indicator light. OUT1 Lights up when output is turned ON Green, OUT2 Lights up when output is turned ON Red for output 27 67. Functions Anti chattering function Display unit switching function Zero clear function Keylock function ISG. Enclosure IP67 Note 2, Fluid temperature range 5 to 80 C No freezing or condensation ZSM1. Environ Operating temperature range Operating 5 to 50 C Stored 10 to 60 C No freezing or condensation. ment Operating humidity range Operating and stored 35 to 85 RH No condensation. Withstand voltage 250 VAC for 1 minute between terminals and housing. Insulation resistance 50 M or more 50 VDC measured via megohmmeter between terminals and housing. Temperature characteristics,25 C reference within operating temperature range. Standards CE UL CSA E216656 RoHS,Pressure sensor Stainless steel 630.
Wetted parts,material Stainless steel 304 port size Rc1 4. Fitting Stainless steel 304,Stainless steel 430 port size NPT1 4 G1 4. Port size 02 Rc1 4 N02 NPT1 4 F02 G1 4 ISO 1179 Note 3. Lead wire with connector Oilproof cable with M12 4 pin pre wired connector 4 cores 4 5 m Conductor O D 0 72 mm Insulator O D 1 14 mm. 225 g port size Rc1 4,Weight 210 g port size NPT1 4 G1 4. 145 g Lead wire with M12 4 pin pre wired connector. Note 1 The NPN and PNP outputs function for a single set point. Note 2 An FKM gasket is used for the product case seal Refer to the Operation Manual at SMC s website for details. Note 3 G1 4 Applicable to ISO 1179 1,Refer to page 84 for the pressure display range. ISE70 75 75H Series,Set Pressure Range and Rated Pressure Range.
Set the pressure to within the rated pressure range. The set pressure range is the range of pressure that is possible in setting. The rated pressure range is the range of pressure that satisfies the specifications accuracy linearity etc on the switch. Although it is possible to set a value outside the rated pressure range the specifications will not be guaranteed even if the value stays. within the set pressure range,Pressure range,100 kPa 0 0 4 MPa 0 5 MPa 1 MPa 10 MPa 15 MPa. For 1 MPa ISE70,For Air 100 kPa 1 MPa,For 10 MPa 0 10 MPa. For General ISE75,Fluids 0 4 MPa 10 MPa,For 15 MPa 0 15 MPa. For General ISE75H,Fluids 0 5 MPa 15 MPa, The ISE75 H switch shows zero 0 when the pressure being applied goes below the lower limit of the set pressure range when the zero cut off display. function is selected,Rated pressure range of switch.
Set pressure range of switch,Internal Circuits and Wiring Examples. NPN 2 outputs NPN 1 output PNP 1 output, The pressure set point for switching the output signal is common to NPN and PNP. Brown DC Brown DC,Black OUT1 NPN Black OUT1 NPN,Main circuit. Main circuit,12 to 24 12 to 24,White OUT2 NPN VDC VDC. White OUT2 PNP,Blue DC Blue DC,PNP 1 output PNP 2 outputs.
Brown DC Brown DC,Black OUT1 PNP Black OUT1 PNP,Main circuit. Main circuit,12 to 24 12 to 24,White N C VDC White OUT2 PNP VDC. Blue DC Blue DC, 2 Color Display Digital Pressure Switch ISE70 75 75H Series. Dimensions,ISE70 75 75H 34,UP DOWN ZSE30,PRESSURE SWITCH. 24 31 15 7 ISE80, Note If it is predicted that the pres Note The connector faces down.
Piping port,sure such as the water hammer,or surge pressure fluctuates. toward the piping Do not,attempt to rotate the, N02 NPT1 4 rapidly refer to the Handling connector as it is not. F02 G1 4 ISO 1179 Precautions stated in the Op rotatable. eration Manual at SMC website 2,http www smcworld com. Bracket mount 34 9 44 5 3 4 PSE,Connector pin number. Color Gray,2 White OUT1 PNP,4 Black OUT1 NPN,5 Output 65.
PRESSURE SWITCH,2 Color Black,1 Brown DC,2 White NC. 60 38 7 35 4 Black OUT1 PNP,24 Output 27 and 67,Color Gray. 1 Brown DC,Piping port OUT2,02 Rc1 4 NPN or PNP,N02 NPT1 4 3 Blue DC. F02 G1 4 ISO 1179,NPN or PNP,Brown 5000 38 5,Lead wire with connector. Lead wire with connector Brown,ZS 31 C Blue,ISE70 75 75H Series.
A Display calibration function G Error function, Fine adjustment of the indicated value of the pressure sensor can be Take the following corrective actions when error occurs. made within the range of 5 of the read value Error LCD. The scattering of the indicated value can be eliminated Description Action. description display,Indicated value of pressure,Eliminate the cause. Over of the over current,Load current of switch by turning off the. current output exceeds 80 mA power supply and,0 Applied pressure error Note 1. OUT2 then turn on it,Indicated value at the time again.
of shipment,Adjustable range of display,calibration function During zero clear. operation pressure over, Note When the display calibration function is used the set pressure value 7 F S is applied. may change 1 digit After 3 second the Perform zero clear. mode will reset to operation again,B Peak Bottom hold function Residual. measurement mode after restoring the, This function constantly detects and updates the maximum and mini 1 F S of the applied pressure to. zero clear range varies an atmospheric, mum pressure values and allows the unit to hold the display value.
between individual pressure condition,C Keylock function. Prevents operation errors such as accidentally changing setting val. ues Supply pressure,exceeds the maximum,D Zero clear function set pressure Reset applied. pressure to a level, The measured pressure reading can be adjusted to zero More spe pressure. Supply pressure is within the set, cifically the factory set reading can be corrected to within 7 F S below the minimum pressure range. set pressure,E Display unit switching function, Display units can be switched with this function Internal data error.
Unit Reading resolution ISE70 ISE75 75H,Internal data error. MPa 0 01 0 1 Turn the power off,System error and turn it on again. kgf cm2 0 1 1,bar Internal data error,psi 1 1 X10,Internal data error. F Anti chattering function, A large bore cylinder or ejector consumes a large amount of air in op If the failure cannot be solved after the above instructions are per. eration and may experience a temporary drop in the primary pres formed please contact SMC for investigation. sure This function prevents detection of such temporary drops in pri Note 1 Output 27 and 67 only. mary pressure as abnormal pressure, Response time selections 20 ms 160 ms 640 ms 1000 ms 2000 ms.
H Zero cut off display function, With the ISE75 series users can enable or disable a function zero cut off display function that displays pressure values of 0 3 MPa or less as. zero 0 4 MPa or less in the ISE75H series, Example pressure displays shading indicates changed displays. ISE75 for 10 MPa, Zero cut off display function ON 0 Displayed as 0 0 4 0 5 0 6 9 9 10 0. Zero cut off display function OFF 0 0 1 0 2 0 3 0 4 0 5 0 6 9 9 10 0. ISE75H for 15 MPa, Zero cut off display function ON 0 Displayed as 0 0 5 0 6 14 9 15 0. Zero cut off display function OFF 0 0 1 0 2 0 3 0 4 0 5 0 6 14 9 15 0. Pressure Display Range, Series Zero cut off display function ON Zero cut off display function OFF.
ISE75 0 0 4 to 10 0 MPa 0 to 10 0 MPa,ISE75H 0 0 5 to 15 0 MPa 0 to 15 0 MPa. The set pressure range does not change when the zero cut off display function is disabled. ISE75 H Series Made to,Made to Order Specifications Order. Please contact SMC for detailed dimensions specifications and lead times. 1 Analog Voltage Output Specifications X500, This product is compatible with NPN open collector 1 output Analog voltage output ISE20. How to Order Refer to How to Order on page 82 for the standard specifications ZSE40. ISE75 H 43 X500 ZSE10,Output Note ZSE80,Note The output is applicable to 43 only. Specifications, Output voltage 1 to 5 V 2 5 F S In rated pressure range PSE.
Analog voltage output Output impedance Approx 1 k,Response time 300 ms or less IS. 1 1 Brown DC ISG,Connector pin number 2 White Analogue output. 3 Blue DC ZSM1,3 4 4 Black OUT1 NPN, Models other than above are the same specifications as standard.

Related Books

Series AFF - SMC ETech

Series AFF SMC ETech

Main Line Filter Series AFF Order Made Series AFF is mounted to main piping to remove impurities like oil, water and foreign matter in compressed air. It improves the function of downward dryer, extends the life of precision filter and prevents trouble with the equipment. How to Select Model Graph of Max. Flow Follow the procedure given below to select the model in accordance with the inlet ...

RB Series - SMC ETech

RB Series SMC ETech

Shock Absorber RB Series 1. Type of Impact Type of impact Collision speed (1) ? Kinetic energy E1 Thrust energy E2 Absorbed energy E Corresponding (2) mass of

Stopper Cylinder - SMC ETech

Stopper Cylinder SMC ETech

How to Order 15 M9BW 15 20 20 With auto switch (Built-in magnet) RSQ B RSDQ B D D With auto switch Standard Auto switch ? For the applicable auto switch

P0893-0946-ITV-CS3e - SMC ETech

P0893 0946 ITV CS3e SMC ETech

Applicable Fieldbus protocols Note 2) ITV1000. Dimensions in parentheses ( ) are for the CC-Link or PROFIBUS DP. 50 50 98(108) Note 2) Compact/lightweight (Integrated ...

Industrial Filters - SMC ETech

Industrial Filters SMC ETech

Series FGD/FGE/FGG/FGA/FGB/FGC Industrial Filters Vessel Series/Elements FGA type Sintered metal FGB type FGC type FGG type Elements FGE type Micromesh

Mechanical Valve Series VM - SMC ETech

Mechanical Valve Series VM SMC ETech

2-41 Series VM Warning Mounting Conditions for mechanical operation Do not move the mechanical operation beyond the operating limit position, as this could damage the mechanical valve itself

YOUR ELECTRONICS MAGAZINE ISSUE 4

YOUR ELECTRONICS MAGAZINE ISSUE 4

0 6 E U SER I N T R F A C E 2 4 S WIT C H I N G C A P A B I L I T I E S 1 4 G E T R E A D Y F O R 4 G eTech - ISSUE 4 03ELE_0010_1010 INSIDE eTech Welcome to your latest edition of eTech.

3 Port Solenoid Valve - SMC ETech

3 Port Solenoid Valve SMC ETech

[Option] Rubber Seal Cover Series SYJ300/500/700 3 Port Solenoid Valve 1727 SYJ VQZ VP VG VP3

Flow Switches Series PF2 , IF - SMC ETech

Flow Switches Series PF2 IF SMC ETech

Series PF2 , IF Diaphragm Style Flow Switch: Series IFW Paddle Style Flow Switch: Series IF3 Flow Switches Model Contacts Port size (Rc, NPT, G) IFW510

3 Port Solenoid Valve Series VQ100 - SMC ETech

3 Port Solenoid Valve Series VQ100 SMC ETech

Manual Override Operation If the manual override is manipulated, since any connected equipment will be activated, make sure to be done only after no

5 Port Mechanical Valve Series VZM500 - SMC ETech

5 Port Mechanical Valve Series VZM500 SMC ETech

Straight plunger VZM550-01-05 VM-08C VM ... 5 Port Mechanical Valve Series VZM500 S A V A ... ? 0.5 MPa supply Series VZM500 Selector (2 position) VZM550-01-34R/B/G ...

3 Port Mechanical Valve Series VM400 - SMC ETech

3 Port Mechanical Valve Series VM400 SMC ETech

3 Port Mechanical Valve Series VM400 Specifications ... Straight plunger VM430-01-05 VM-08A VM-07AS VM-07A VM-06AS VM-06A ... VM430-01-34R VM430-01-34B VM-34AB ...

Flow Switch Diaphragm Type Flow Switch IFW5 - SMC ETech

Flow Switch Diaphragm Type Flow Switch IFW5 SMC ETech

C3604B CAC408 NBR About the use of ?, please confirm SMC. IFW5 10 N 03 1 1 Diaphragm type flow switch Body size Thread type Nil N F Rc G NPT Port size Light

LEC 1 P N 1 LEFS16A-400 - SMC ETech

LEC 1 P N 1 LEFS16A 400 SMC ETech

How to Order [CE-compliant products] EMC compliance was tested by combining the electric actuator LE series and the controller LEC series. The EMC depends on the ...