Digico Sd Rack-Books Pdf

DiGiCo SD Rack
27 Mar 2020 | 28 views | 0 downloads | 13 Pages | 763.81 KB

Share Pdf : Digico Sd Rack

Download and Preview : Digico Sd Rack


Report CopyRight/DMCA Form For : Digico Sd Rack



Transcription

1 1 Introduction 1 4, 1 1 1 SD Rack Unit and Modules Installation Notes 1 4. 1 2 SD Rack Power 1 6,1 3 SD Rack Clocking 1 6,1 4 SD Rack Cards 1 6. 1 4 1 Analogue Mic Line Input card ADC 1 7,1 4 2 Analogue Line Output card DAC 1 7. 1 5 Splits Gain Tracking 1 7,1 5 1 Split Options 1 7. 1 5 2 Gain Tracking 1 7,1 6 Using the SD Rack Menu System 1 8.
1 6 1 PSU Readings 1 10,1 6 2 I O Card Code Versions 1 10. 1 6 3 MADI Card Code Versions 1 10,1 6 4 Rack Type 1 10. 1 6 5 Rack Defaults 1 10,1 6 6 Main Display 1 10,1 6 7 Optocore ID Fibre Speed 1 11. 1 6 8 USB Rack Control 1 11,1 6 9 Rack Sync Source 1 11. 1 6 10 Rack Sync Order 1 11,1 6 11 Rack Sample Rate 1 12.
1 6 12 Rack Routing Mode 1 12,1 6 13 Rack Routing Order 1 12. 1 6 14 Rack Main and Aux Splits 1 13,1 6 15 Rack Card Splits 1 13. 1 1 Introduction,1 1 1 SD Rack Unit and Modules Installation Notes. The SD Rack Unit is a 19 inch chassis with a control panel and PSUs at the top It is a standard 19 rack mount wide 365mm deep. excluding connectors and 10u 445mm high,Rack Mains Earthing. The SD Rack Unit must be earthed to the mains earth according to the safety instructions included with the mixer system. The rack has twin supplies each with their own separate mains power connections with 2 IEC mains inputs per rack which must be. separately connected to the mains earth,Rack Power Supply Installation.
The SD Rack Unit contains 2 model MOD SDR PSU From s n 6221 1203 these are supplied with listed component approval to UL. EN IEC CSA 60950 1 Units built to this standard are marked with the ETL mark These units are intended for operation ONLY in the. SD Rack No attempt should be made to operate or install these supplies other than in the SD Rack only in the manner described here. The rack will operate on only 1 supply Supply units on the SD Rack can be switched off removed and replaced whilst the other is use. hot swappable,Rack Power Supply Cooling, The SD Rack Unit has twin supplies each with their own separate mains power connections with 2 IEC mains inputs per rack. At least 1U 45mm of space should be left above and below the rack unit to allow ventilation and to prevent heat. transfer from adjacent equipment At least 100mm 4 should allowed to side of the units to allow heat dissipation. At least 100mm 4 free air should be left at both the front plain side and the rear connector side of the rack to allow ventilation. However this clearance is usually required at a rack face and to allow connector access at the rear in any case. Under no circumstances should the fan outlets be blocked or restricted. The supply approval covers use in ambient air temperatures up to 35 deg C Operation in temperatures above this should be avoided. Rack Control Panel Connections,MADI I O BNC 4 sockets 2 Pairs of I O to Console. MADI output split BNC 2 sockets to Console or recorder etc. Optocore HMA 2 Bidirectional dual connector optional Neutrik 2 x OpticalCON Duo optional ST Optical x 4 optional. Word Clock Out BNC socket 48 96 KHz 5V p p,Word Clock In BNC socket 48 96 KHz 5V p p max. USB type B,Mains Power IEC power x 2 Dual redundant supplies. Stage rack 200VA run,FOH rack 200VA run,100V 240V 50 60Hz auto sense.
Requires 2 separate mains connections,Input Output Slots. Below the panel the Rack Unit has Input and Output slots Each of these slots can be filled with a different Rack Module providing an I. O system which is configured according to model or user requirements SD modules in the SD Rack can be removed and replaced. whilst others are in use hot swappable,Rack Module Inputs and Outputs. There are different Rack Modules for interfacing to different digital and analogue devices Each Rack Module carries eight channels. The modules fall into two broad groups those which carry only inputs or outputs and those which carry both input and output. signals Output modules must be installed in Output slots while Input and I O modules must be installed in Input slots The rack can be. fitted with up to 7 input or I O modules and 7 output modules less where I O modules fitted. Rack Module Connections, Audio connections to the Rack Modules are made using appropriate connectors for the type of module See the specifications for a list. of the different connectors used in the Rack Modules. Rack Signal Earthing, The analogue earthing requirements of the Rack unit is similar to those of a conventional large analogue console All analogue. inputs and outputs are balanced and symmetrical but not floating because of their transformerless design Installers should use. good earthing practice as with any large audio installation Digico can provide copies of AES papers on this subject upon request. Hot Swappable Rack MADI OPTO Hot Swappable,Dual Redundant PSU Pod Dual Redundant PSU.
Input or Bidirectional Cards Output Cards,Optocore Interface. Word Clock,External USB Control Port,AUX MADI AUX MADI Split. MAIN MADI MAIN MADI Split,1 2 SD Rack Power, The SD rack has dual redundant hot swappable power supplies The rack should be operated with both powersupplies on whenever. 1 3 SD Rack Clocking, The SD Rack will receive clock sync from the connected console in normal operation It can run run at 48KHz or 96khz when clocked by. the console It is capable of running at 192KHz but this has not yet been implemented in current console software. The SD Rack can also receive sync from its own internal clock at several different sample rates see section 1 6 9 Rack Sample Rate. Additionally the rack can receive sync from an external word clock source when the word clock is connected to the rack s word clock in. 1 4 SD Rack Cards, Several rack I O card options are available I O cards normally provide blocks of 8 signals.
A rack can be fitted with up to 14 I O cards providing up to 56 inputs and 56 outputs. Card options are,Analogue Mic Line Input card on XLR. Analogue Line Output card on XLR,AES Input card on XLR or BNC. AES Output card on XLR or BNC,AES Bidirectional I O card on XLR or BNC. Aviom card 16 outputs occupying 2 rack slots CAT5 connector. AES42 Mic Input card on XLR,HD SDI 8 Channel Embed De Embed I O card on BNC. 1 4 1 Analogue Mic Line Input card ADC, The 8 Mic Line input ADC card has 2 indicators on each socket.
The orange indicator shows the status of 48V Phantom Power On Off. The green indicator shows signal present and this turns red when the signal is close to clipping. 1 4 2 Analogue Line Output card DAC, The 8 Line output DAC card has 2 indicators at the bottom of the card. The red indicator shows the status of Gain Tracking On Off. The yellow indicator shows the status of the card Split On Off. 1 5 Splits Gain Tracking,1 5 1 Split Options,The SD Rack has several different Split options. 1 Each input slot block of 8 sockets on an input card can be split to its relevant output slot So slot 1 would be split to slot 8 slot 2 to. slot 9 and so on These split signals can be automatically Gain Tracked so that any change in the analogue gain on the input socket is. compensated by the opposite change in digital trim on the relevant output socket. The output cards have LED indicators showing Split ON OFF and Gain Tracking ON OFF status. 2 There are 2 dedicated MADI split ports on BNC connectors labelled MADI Split Main MadiSM and MADI Split Aux MadiSX. These ports can provide either 2 independent split signals at 48KHz or a pair of split signals that contain MADI channels 1 28 and 29 56. These outputs can also have automatic Gain Tracking applied to them on a per split basis Eg Main Split with Gain Tracking On and Aux. Split with Gain Tracking Off,1 5 2 Gain Tracking, Gain Tracking can be controlled from the Rack LCD Menu system or optionally by an SD Series console. With Gain Tracking switched ON the digital trim on the split outputs works in direct relation to the analogue gain that is applied to the. relevant same numbered input socket Any change in the analogue gain at the input results in the opposite change being applied to the. digital trim of the output split socket, If the analogue gain of an input socket starts at 0dB and with Gain Tracking On is raised to 10dB the output split level will remain. constant because it will have had a 10dB change applied to it in real time. The correct procedure to follow is to set an acceptable level of analogue gain on each input before switching the Gain Tracking function. on Once the Gain Tracking function is active it should not be switched off without careful consideration. There is also a Gain Track Reset function which sets the split output digital trim to zero This function should also be treated with due care. because using it on an active split will potentially change the output level by a large amount. 1 6 Using the SD Rack Menu System, The LCD Menu System on the rack MADIPod is normally in a locked state and cannot be accessed.
The main display will be visible and if the rack is not connected to an SD console the background colour will be light blue. If an SD console is connected and the rack is correctly receiving control data from it the display will flash green. Pressing and holding the 2 buttons marked with left and right arrows for 2 seconds unlocks the Menu System During the 2 seconds the. display will be red and say Locked and when unlocked the display will turn green and say Unlocked. The Up Down buttons scroll through the pages in the Menu System and the Left Right buttons are used to select each item within pages. that have multiple items When an item s value can be changed the Up Down arrows are used for this. If the rack is left in an idle state for 2 minutes it will relock itself. Please refer to the following diagram for menu navigation details. 1 6 1 PSU Readings, This page shows readings for all rack PSU voltages No adjustment is possible from the menu. 1 6 2 I O Card Code Versions, This page shows the type of card detected in each rack slot and the firmware version installed on the card. SLx indicates slot number in the range SL1 to SL14 reading left to right in the rack Date codes are DD MM YY. No adjustment is possible from the menu,1 6 3 MADI Card Code Versions. This page shows the MADIPod firmware versions installed on the rack HOST FPGA and FONT date codes are DD MM YY. No adjustment is possible from the menu,1 6 4 Rack Type. This page shows the SD Rack type that the MADIPod is currently for Options are SD Rack SD MINI Rack and SD NANO Rack Set this. according to the rack type being used,1 6 5 Rack Defaults.
This page allows the user to set all rack parameters to their DEFAULT values. When the display shows Default Rack Yes press the Right arrow button to confirm. The display will now show Default Rack Sure press the Right arrow button to confirm. Using the Left arrow button will navigate back from Sure to Yes. 1 6 6 Main Display, The main display is always visible when the Menu System is in a locked state. It indicates, r The type of input output being routed M MADI O Optocore. s The rack sync source M MADI O Optocore Int Internal W Word Clock. idxx The Optocore ID of the rack, xxK The sample rate being used by the rack eg 48KHz. WMXO The sync priority order which defaults to Word Clock MADI Main MADI Aux Optocore. An upward arrow will appear underneath each of the available sources of sync. Thus if there is no valid Word Clock or MADI input to the rack it will automatically sync to Optocore if present. If a valid Word Clock input is then connected to the rack this will automatically become the sync source for the entire Optocore system. If multiple valid Word Clock inputs are connected to different racks the rack with the lowest optocore ID that is receiving a Word Clock will. become the sync source for the entire Optocore system. 1 6 7 Optocore ID Fibre Speed, These pages show the Optocore ID of the rack in range of 11 to 24 and the fibre speed which is either 1GB or 2 GB. Each rack requires a unique ID so that it can be recognised by the rest of the Optocore system To change the ID scroll with the Left. Right buttons until you reach the required number, The rack fibre speed needs to be set to the same value as all other devices in the Optocore system The Default is 2GB and this should.
not be changed unless you have special requirements There are two possible reasons to change the fibre speed to 1GB. 1 If you require distances of optical fibre greater than 350M between individual devices. 2 You require compatibility with Optocore s own I O units some of which will only operate at the 1GB fibre speed Please consult your. Optocore device documentation for the fibre speed specifications. NOTE Using a fibre speed of 1GB will restrict the system s Optocore fibre channel count to 224 I O at 96KHz. 1 6 8 USB Rack Control, This page allows selection of which rack component can be addressed by the rack USB port. When set to Opto the internal Optocore board can be addressed for the reprogramming of Optocore firmware this is not required. unless under specific instruction from your distributor or DiGiCo Support. When set to Rack the general rack control system can be addressed this feature is not yet implemented Nov 2010. The Default setting is Rack,1 6 9 Rack Sync Source. This page allows selection of the rack sync source. The Default setting is AUTO which allows automatic sync selection in the order selecetd in the Rack Sync order page where the default

Related Books

Shortcut to Spanish

Shortcut to Spanish

Shortcut to Spanish Component 4 Power words The 100 most frequently used words in Spanish Top 100 Word Top 100 words are in red These top 100 words are simply the most frequently used words in Spanish In fact studies have shown that as few as 100 words are used over and over in 50 of all communication

MODELABMY2K2 INSTRUCTIONMANUAL Bread Machine Digest

MODELABMY2K2 INSTRUCTIONMANUAL Bread Machine Digest

WELBILT HOUSEHOLD USE ONLY The 5 bread machines in this manual make REGULAR 1 lb or LARGE 1 1 2 lb loaves of breads The ABM8200 or the ABM2H60 also makes EXTRA LARGE 2 lb loaves of breads The ABM3500 and ABM1H70 have 28 settings The ABMY2K2 has 31 settings The ABM2H60 and ABM8200 have 41 settings See Setting Chart page 10 Special ULTRA FASTsetting allows you to complete

THE BREAD MACHINE Creative Homemaking

THE BREAD MACHINE Creative Homemaking

THE BREAD MACHINE White bread series WELBILT French bread series Sweet bread series Handmade bread series 21 4 Tsp Dry Yeast 3 Cups Bread Flour 11 2 Tsp Salt 11 2 Tbsp Sugar 11 2 Tbsp Dry Skim Milk 41 2 Tsp Shortening or Sweet Butter 11 2 Cups Less 3 Tbsp Lukewarm Water Baking Process 1 Put dry yeast in inner pot Dry yeast 4 Press the Select button for white bread

Fundamentals of Sustainable Investment

Fundamentals of Sustainable Investment

FUNDAMENTALS OF SUSTAINABLE INVESTMENT A GUIDE FOR FINANCIAL ADVISORS 6 Welcome March 2019 Sustainable investing is evolving rapidly Each new week brings an article documenting the burgeoning demand from clients for sustainability focused options or announcements of new environmental social and governance ESG related products Like many other financial advisors you probably find

An Introduction to Investment in Commercial Aircraft

An Introduction to Investment in Commercial Aircraft

Many categories of traditional fixed income investments including leveraged loans middle market lending mezzanine funds and other direct lending strategies pose more downside risk to investors compared with specialist hard asset strategies 1987 2010 Lien Position Recovery Rates Loans 80 3 Bonds Sr Secured 63 5 Sr Unsecured 49 2 Sr Subordinated 29 4 Subordinated 29 3 Jr

Related Download Solutions Manual Fundamentals Of

Related Download Solutions Manual Fundamentals Of

Related Download Solutions Manual Fundamentals Of Investments 7th Edition by Jordan Miller Dolvin Chapter 01 A Brief History of Risk and Return Multiple Choice Questions 1 The total dollar return on a share of stock is defined as the A change in the price of the stock over a period of time B

The Fundamentals of Investing Vocabulary List

The Fundamentals of Investing Vocabulary List

The Fundamentals of Investing Vocabulary List TERM DEFINITION 1 Bond A form of lending to a company or the government city state or federal 2 Brokerage firm Facilitates the buying and selling of investments from a stock exchange

Retirement amp Fundamentals of Investments IL Vocational

Retirement amp Fundamentals of Investments IL Vocational

Investments offering the potential for higher rates of return also involve a higher degree of investment risk Actual results will vary 17 Rebalance Regularly After a major lifestyle change Typically at least once a year As the result of a change in your investing outlook Only 48 of Americans have calculated how much they will need to retire comfortably Those who have calculated their needs

PTO INSTALLATION amp OWNER S MANUAL

PTO INSTALLATION amp OWNER S MANUAL

pto installation amp owner s manual warning read manual completely including these warnings and operator s instructions in section 3 read and understand entire manual before installation or operation of pto and driven equipment always disengage the pto when the driven equipment is not in operation do not attempt to install or service any power take off with the truck engine

P O Box 5887 Denver CO 80217 5887 Interference Engines

P O Box 5887 Denver CO 80217 5887 Interference Engines

service please contact the local automotive parts store that sold the belt The parts store will contact a Gates repre The parts store will contact a Gates repre sentative to implement the warranty process

HEAVY DUTY SOLUTIONS OTC Tools

HEAVY DUTY SOLUTIONS OTC Tools

Application 1998 1 2 2002 Dodge pickups and vans with 5 9L 24 valve Cummins diesel turbo engine 6087 GM Injection Pump Wrench Set Use to loosen or tighten injection pump retaining bolts whenever pump timing adjustment or pump service is required Services 1996 1999 GM full size 2 and 4 wheel drive trucks vans and Suburbans