Centrifuge Product Guide Lennox-Books Pdf

CENTRIFUGE PRODUCT GUIDE Lennox
17 Dec 2019 | 52 views | 0 downloads | 60 Pages | 3.12 MB

Share Pdf : Centrifuge Product Guide Lennox

Download and Preview : Centrifuge Product Guide Lennox


Report CopyRight/DMCA Form For : Centrifuge Product Guide Lennox



Transcription

Table of Contents,About Hettich 1,Spinning Guide 2 5. MANUAL Centrifuge 6 7,Micro Centrifuges,MIKRO 120 8 9. MIKRO 200 10 11,MIKRO 220 12 15,Basic Centrifuges,EBA 20 16 17. EBA 20S 18 19,EBA 21 20 21,ROTOFIX 32A 22 25,Standard Centrifuges. UNIVERSAL 320 26 29,ROTINA 380 30 33,ROTINA 420 34 37.
ROTANTA 460 38 41,Floor Standing Centrifuges,ROTANTA 46RSC Robotic 42 43. ROTIXA 50 44 47,ROTO SILENTA 630RS 48 51,Accessories. Cytology 52,Cabinets 53, more info online north america hettweb com worldwide hettichlab com III. welcome to Hettich,For more than 100 years Andreas Hettich GmbH. Co KG has been a leader in centrifugation,technology innovation and safety.
Hettich designs builds and manufactures its products. from its family run headquarters in Tuttlingen, Germany It is this family tradition and devotion that. continues to allow Hettich to develop nothing but the. nest in quality products and customer satisfaction. Hettich is recognized as one of the top clinical research. centrifuge manufacturers in the world Applications. include separation of blood and uids in blood banks. and clinical laboratories In the research eld our,centrifuges are used to separate solutions to. extract DNA proteins and enzymes,We o er a full range of centrifuges. from small benchtop micro,centrifuges to large oor. standing models and,also provide custom built,solutions for any.
lab project,Andreas Hettich GmbH Co KG,Tuttlingen Germany. TUB E T YP E,Round Round,Microliter,Spinning Bottom Bottom. ml 1 5 2 0 15 50,mm 11 x 38 17 x 100 34 x 100,C E N T R IFU GE MAX CAPACIT Y. MIKRO 120 24,MIKRO 200 30,MIKRO 220 48 12 6,EBA 20 20S 8. EBA 21 30 12 6,ROTOFIX 32A 32 6,UNIVERSAL 320 30 32 6.
S TA NDA R D,ROTINA 380 30 52 12,ROTINA 420 30 72 16. ROTANTA 460 30 76 16,ROBOTIC 76 16,ROTIXA 50 120 24. ROTO SILENTA 180 36,Indicates max capacity on MIKRO 220R. THE TABLE ABOVE IS BASED ON THE MAXIMUM QUANTITY A CENTRIFUGE CAN HOLD PER RUN IT IS A. GUIDE TO HELP YOU QUICKLY SELECT THE CORRECT CENTRIFUGE MODEL FOR ADDITIONAL CENTRIFUGE. CONFIGURATIONS PLEASE VISIT hettichlab com OR CALL CUSTOMER SERVICE AT 49 0 7461 705 201. T U B E T YP E,Round Round Conical,Blood Blood Conical. Bottom Bottom Skirted,100 250 15 50,44 x 100 65 x 115 17 x 120 29 x 115.
75 100 75 100,MAX CA PACIT Y,12 8 12 6 3 12,12 8 12 6 3 20. 4 32 20 28 16 32 8 22,4 32 28 32 8 26,4 4 64 52 36 16 30. 4 84 104 72 52 20 34,12 40 x 115 mm,6 108 96 88 56 28 38. 12 40 x 115 mm,4 96 96 56 24 42,12 40 x 115 mm,16 6 120 120 92 32 24 44. 24 6 180 180 138 48 36 48,Continued on next page, more info online north america hettweb com worldwide hettichlab com 3.
TUB E T YP E,Large High High,conical capacity capacity. Continued from,previous page,ml 250 500 250 600 750. mm 61 x 122,C E N T R IFU GE MAX CAPACIT Y,EBA 20 20S. ROTOFIX 32A,UNIVERSAL 320,S TA NDA R D,ROTINA 380 4 x 290. ROTINA 420 4 4 x 600,ROTANTA 460 4 6 4,ROTIXA 50 4 6 4.
ROTO SILENTA 6 6 6, THE TABLE ABOVE IS BASED ON THE MAXIMUM QUANTITY A CENTRIFUGE CAN HOLD PER RUN IT IS A. GUIDE TO HELP YOU QUICKLY SELECT THE CORRECT CENTRIFUGE MODEL FOR ADDITIONAL CENTRIFUGE. CONFIGURATIONS PLEASE VISIT hettichlab com OR CALL CUSTOMER SERVICE AT 49 0 7461 705 201. T U B E T YP E,Blood bags PCR strips Plates Cytology. capacity capacity,1 000 2 000 450 8 x 0 2,180 x 150 86 x 128. 96 x 176 x 15,MAX CA PACIT Y,24 x 8 10 8 26,24 x 8 10 8 30. 48 x 8 16 8 34,4 48 x 8 24 16 38,48 x 8 24 42,4 4 48 x 8 16 12 44.
more info online north america hettweb com worldwide hettichlab com 5. Light weight portable centrifuge,Portable and compact. Self lubricating gear,Virtually maintenance free, Conical and round bottom 4 place rotor systems available. Specifications,Centrifuge Manual,Max Capacity 4 x 15 ml. Max RPM RCF,Swing out 50 3 000 1 076,Swing out 90 3 000 1 300. Dimensions HxWxD 285 x 140 x 175 mm 11 25 x 5 5 x 7. Weight 0 9 kg 2 lbs,Cat No w out rotor 1011,Cat No 50 rotor 1025 round bottom conical tubes.
Cat No 90 rotor 1014 conical tubes only,Common rotor packages. ROUND BOTTOM CONICAL TUBES,Qty Capacity Rotor Bucket RPM RCF. 4 15 ml 1025 3 000 1 076,CONICAL TUBES ONLY,Qty Capacity Rotor Bucket RPM RCF. 4 15 ml 1014 3 000 1 300,Additional images,ROTOR 1025 ROTOR 1014. more info online north america hettweb com worldwide hettichlab com 7. Economy microliter centrifuge,Ultra compact with small footprint.
24 place rotor including autoclavable,and phenol resistant lid with bio containment. Auto imbalance detection and shut o,Lid locking and holding. Motor overheating protection,Specifications,Centrifuge MIKRO 120. Max Capacity 24 x 1 5 2 0 ml,Max RPM RCF 14 000 18 407. Dimensions HxWxD 199 x 231 x 292 mm 8 x 9 x 11 5,Weight 7 kg 15 lbs.
Cat No 240V 1204,115V 1204 01,Common rotor packages. MICROLITER TUBES,Qty Capacity Rotor Bucket Adapter RCF. 24 0 2 2 0 ml 1242 18 407,0 2 0 4 ml 2024,0 5 0 8 ml 2023. 1 5 ml 2031,Additional images,ROTOR 1242, Form fitting adapter phenol resistant for centrifugation at high speeds. Including autoclavable and phenol resistant lid with bio containment. more info online north america hettweb com worldwide hettichlab com 9. Standard microliter centrifuge,Available in non refrigerated 200 and.
refrigerated 200R versions,Choice of 24 or 30 place rotor PCR strip rotor. or Cryo tube rotor,Bio containment autoclavable,phenol resistant lids available. Fast Cool function down to 4 C in 10 15 minutes,Specifications. Centrifuge MIKRO 200 MIKRO 200R,Max Capacity 30 x 0 2 2 0 ml. Max RPM RCF 15 000 21 382,Temperature Control 10 C to 40 C.
Dimensions HxWxD 260 x 275 x 344 mm 260 x 281 x 547 mm. 10 25 x10 75 x13 5 10 25 x 11 x 21 5,Weight 11 5 kg 25 25 lbs 28 kg 61 75 lbs. Cat No 240V 2400 2405,115V 2400 01 2405 01,Common rotor packages. MICROLITER TUBES,Qty Capacity Rotor Accessories RCF. 24 0 2 2 0 ml 2424 B 21 382,30 0 2 2 0 ml 2427 A 2425 2423 20 627. 30 0 5 ml 2430 B 20 376,CRYO TUBES,Qty Capacity Rotor Accessories RCF.
20 1 8 ml 2426 B 2425 2423 21 130,PCR STRIPS,Qty Capacity Rotor Accessories RCF. 4 8 x 0 2 ml 2418 A E2040 14 338,Additional images. MIKRO 200R ROTOR 2427 A ROTOR 2418 A,Lid E3243 Included. info online Phenol, north america hettweb com resistant lidhettichlab com. worldwide autoclavable 11, Bio containment lid autoclavable Optional snap on lid.

Related Books

The Need to Implement and Evaluate Telehealth Competency ...

The Need to Implement and Evaluate Telehealth Competency

Counseling Association (ACA), Marriage and Family Therapy (AAMFT), Psychology (American and Canadian Psychological Associations), Social Work, and Psychiatry professions. The framework of ACGME domains used, as for the TP competencies [6, 7], and rated common clinical skills (e.g., informed consent, assessment, triage, treatment

the skyscraper 2008 05

the skyscraper 2008 05

The Skyscraper May 2008 2 Friday 7:30 pm May Meeting with Arne Henden Seagrave Memorial Observatory 3 Saturday 1:30 pm - 9:30 pm ASSNE Astronomy Day Barrington Green 8:00 pmPublic Observing Night & Variable Star Workshop

Foodservice Food Waste Action Guide - ReFED

Foodservice Food Waste Action Guide ReFED

ReFED | Foodservice Food Waste Action Guide 4 SOLUTIONS OVERVIEW ReFED has identified 15 solutions for foodservice companies (10 from the Roadmap and five that are new solutions or adapted from the Roadmap). For more detail on each of the solutions, see Appendix A. FOOD RECOVERY HIERARCHY ReFED has adapted the Environmental Protection Agency (EPA) Food Recovery Hierarchy framework to ...

Behavioral Intervention Strategies - Milwaukee Public Schools

Behavioral Intervention Strategies Milwaukee Public Schools

Behavioral Intervention Strategies An important goal in education is for all students to be successful in school and in life. Behavioral Interventions are essential for providing behavioral support to those students who display challenging behaviors. Interventions lead students to improved behavior so they can achieve success. Different types of student behavior require different types of ...

IMPACT ASSESSMENT OF THE SOLAR ELECTRIFICATION OF MICRO ...

IMPACT ASSESSMENT OF THE SOLAR ELECTRIFICATION OF MICRO

productive impacts of Solar Home Systems on households and micro enterprises as well as the impact of the support of the activities of the Promotion of Renewable Energy and Energy Efficiency Programme (PREEEP) on the development of rural solar markets in Uganda.

1.The grouping of objects or events based on similar 8 ...

1 The grouping of objects or events based on similar 8

density values are indicated for each substance. Substance C is a liquid in a graduated cylinder. [Note that 1 cubic centimeter = 1 milliliter. Objects are not drawn to scale.] A) A and B B)B and E C) C and D D) A and E Which two substances could be made of the same material?

Stall/Post-Stall Modeling of the Longitudinal ...

Stall Post Stall Modeling of the Longitudinal

The use of simulators has been common practice in the past 30 years for pilot training. Simulators allow for pilot training in real world situations and are achieved by ensuring that the simulators mimic the aircraft and environment as realistically as possible. The critical limitation common in most simulators is

Describing Your Data: Frequencies, Cross Tabulations, and ...

Describing Your Data Frequencies Cross Tabulations and

Describing Your Data: Frequencies, Cross Tabulations, and Graphs Learning Objectives: By the end of this chapter you should be able to: 1. Define and describe the terms frequency and frequency distribution. 2. Define and describe the terms relative frequency, percentage frequency, and cumulative percentage frequency. 3. Construct frequency tables for nominal and ordinal data. 4. Construct ...

IEEE Les s on Pl an: Rubber Band Racers

IEEE Les s on Pl an Rubber Band Racers

In "Rubber Band Racers" lesson students explore rubber band car design. Students work in teams of "engineers" to design and build their own rubber band car out of everyday items. They test their rubber band cars, evaluate their results, and present to the class.

MAD DOG 2004 - Libero.it

MAD DOG 2004 Libero it

l'assistente di volo ci chiama con l'interfono e ci dovrebbe dire "LUCI EMERGENZA, OK". A questo punto portiamo lo switch lo riportiamo in pos ARM controlliamo sull'EOAP per verificare cha la luce di prima si sia spenta. Regoliamo le Luci dei vari pannelli. Facciamo il test "dell'albero di natale" (ndA) premendo il pulsante ANNUN/DIGITAL LTS TEST controlliamo tutte le luci. Controlliamo il ...